97 research outputs found
Noise properties of high-T-c superconducting flux transformers fabricated using chemical-mechanical polishing
Reproducible high-temperature superconducting multilayer flux transformers were fabricated using chemical mechanical polishing. The measured magnetic field noise of the flip-chip magnetometer based on one such flux transformer with a 9 x 9 mm(2) pickup loop coupled to a bicrystal dc SQUID was 15 fT/Hz(1/2) above 2 kHz. We present an investigation of excess 1/f noise observed at low frequencies and its relationship with the microstructure of the interlayer connections within the flux transformer. The developed high-T-c SQUID magnetometers may be advantageous in ultra-low field magnetic resonance imaging and, with improved low frequency noise, magnetoencephalography applications
The role of kinetic inductance on the performance of YBCO SQUID magnetometers
Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa2Cu3O7-x (YBCO) because lower SQUID inductance L leads to lower flux noise, but also weaker coupling to the pickup loop. In order to optimize the SQUID design, we combine inductance simulations and measurements to extract the different inductance contributions, and measure the dependence of the transfer function V Φ and flux noise on L. A comparison between two samples shows that the kinetic inductance contribution varies strongly with film quality, hence making inductance measurements a crucial part of the SQUID characterization. Thanks to the improved estimation of the kinetic inductance contribution, previously found discrepancies between theoretical estimates and measured values of V Φ and could to a large extent be avoided. We then use the measurements and improved theoretical estimations to optimize the SQUID geometry and reach a noise level of = 44 fT/√SRC="sustab6014ieqn4.gi for the best SQUID magnetometer with a 8.6 mm
7 9.2 mm directly coupled pickup loop. Lastly, we demonstrate a method for reliable one-time sensor calibration that is constant in a temperature range of several kelvin despite the presence of temperature dependent coupling contributions, such as the kinetic inductance. The found variability of the kinetic inductance contribution has implications not only for the design of YBCO SQUID magnetometers, but for all narrow linewidth SQUID-based devices operated close to their critical temperature
On-scalp MEG sensor localization using magnetic dipole-like coils: A method for highly accurate co-registration
Source modelling in magnetoencephalography (MEG) requires precise co-registration of the sensor array and the anatomical structure of the measured individual\u27s head. In conventional MEG, the positions and orientations of the sensors relative to each other are fixed and known beforehand, requiring only localization of the head relative to the sensor array. Since the sensors in on-scalp MEG are positioned on the scalp, locations of the individual sensors depend on the subject\u27s head shape and size. The positions and orientations of on-scalp sensors must therefore be measured a every recording. This can be achieved by inverting conventional head localization, localizing the sensors relative to the head - rather than the other way around. In this study we present a practical method for localizing sensors using magnetic dipole-like coils attached to the subject\u27s head. We implement and evaluate the method in a set of on-scalp MEG recordings using a 7-channel on-scalp MEG system based on high critical temperature superconducting quantum interference devices (high-T-c SQUIDs). The method allows individually localizing the sensor positions, orientations, and responsivities with high accuracy using only a short averaging time (<= 2 mm, < 3 degrees and < 3%, respectively, with 1-s averaging), enabling continuous sensor localization. Calibrating and jointly localizing the sensor array can further improve the accuracy of position and orientation (< 1 mm and < 1 degrees, respectively, with 1-s coil recordings). We demonstrate source localization of on-scalp recorded somatosensory evoked activity based on coregistration with our method. Equivalent current dipole fits of the evoked responses corresponded well (within 4.2 mm) with those based on a commercial, whole-head MEG system
Detection of interictal epileptiform discharges: A comparison of on-scalp MEG and conventional MEG measurements
Objective: Conventional MEG provides an unsurpassed ability to, non-invasively, detect epileptic activity. However, highly resolved information on small neuronal populations required in epilepsy diagnostics is lost and can be detected only intracranially. Next-generation on-scalp magnetencephalography (MEG) sensors aim to retrieve information unavailable to conventional non-invasive brain imaging techniques. To evaluate the benefits of on-scalp MEG in epilepsy, we performed the first-ever such measurement on an epilepsy patient. Methods: Conducted as a benchmarking study focusing on interictal epileptiform discharge (IED) detectability, an on-scalp high-temperature superconducting quantum interference device magnetometer (high-Tc SQUID) system was compared to a conventional, low-temperature SQUID system. Coregistration of electroencephalopraphy (EEG) was performed. A novel machine learning-based IED-detection algorithm was developed to aid identification of on-scalp MEG unique IEDs. Results: Conventional MEG contained 24 IEDs. On-scalp MEG revealed 47 IEDs (16 co-registered by EEG, 31 unique to the on-scalp MEG recording). Conclusion: Our results indicate that on-scalp MEG might capture IEDs not seen by other non-invasive modalities. Significance: On-scalp MEG has the potential of improving non-invasive epilepsy evaluation. (C) 2020 International Federation of Clinical Neurophysiology. Published by Elsevier B.V
Neural gain control measured through cortical gamma oscillations is associated with sensory sensitivity
Gamma oscillations facilitate information processing by shaping the excitatory input/output of neuronal populations. Recent studies in humans and nonhuman primates have shown that strong excitatory drive to the visual cortex leads to suppression of induced gamma oscillations, which may reflect inhibitory-based gain control of network excitation. The efficiency of the gain control measured through gamma oscillations may in turn affect sensory sensitivity in everyday life. To test this prediction, we assessed the link between self-reported sensitivity and changes in magneto-encephalographic gamma oscillations as a function of motion velocity of high-contrast visual gratings. The induced gamma oscillations increased in frequency and decreased in power with increasing stimulation intensity. As expected, weaker suppression of the gamma response correlated with sensory hypersensitivity. Robustness of this result was confirmed by its replication in the two samples: neurotypical subjects and people with autism, who had generally elevated sensory sensitivity. We conclude that intensity-related suppression of gamma response is a promising biomarker of homeostatic control of the excitation-inhibition balance in the visual cortex
Recommended from our members
Gut microbiome composition in the Hispanic Community Health Study/Study of Latinos is shaped by geographic relocation, environmental factors, and obesity.
Background: Hispanics living in the USA may have unrecognized potential birthplace and lifestyle influences on the gut microbiome. We report a cross-sectional analysis of 1674 participants from four centers of the Hispanic Community Health Study/Study of Latinos (HCHS/SOL), aged 18 to 74 years old at recruitment.Results: Amplicon sequencing of 16S rRNA gene V4 and fungal ITS1 fragments from self-collected stool samples indicate that the host microbiome is determined by sociodemographic and migration-related variables. Those who relocate from Latin America to the USA at an early age have reductions in Prevotella to Bacteroides ratios that persist across the life course. Shannon index of alpha diversity in fungi and bacteria is low in those who relocate to the USA in early life. In contrast, those who relocate to the USA during adulthood, over 45 years old, have high bacterial and fungal diversity and high Prevotella to Bacteroides ratios, compared to USA-born and childhood arrivals. Low bacterial diversity is associated in turn with obesity. Contrasting with prior studies, our study of the Latino population shows increasing Prevotella to Bacteroides ratio with greater obesity. Taxa within Acidaminococcus, Megasphaera, Ruminococcaceae, Coriobacteriaceae, Clostridiales, Christensenellaceae, YS2 (Cyanobacteria), and Victivallaceae are significantly associated with both obesity and earlier exposure to the USA, while Oscillospira and Anaerotruncus show paradoxical associations with both obesity and late-life introduction to the USA.Conclusions: Our analysis of the gut microbiome of Latinos demonstrates unique features that might be responsible for health disparities affecting Hispanics living in the USA
Operation of a high-T SQUID gradiometer with a two-stage Joule-Thomson micro-cooler
Practical applications of high-T SQUIDs require cheap, simple in operation, and cryogen-free cooling. Mechanical cryo-coolers are generally not suitable for operation with SQUIDs due to their inherent magnetic and vibrational noise. In this work, we utilized a Joule-Thomson microfluidic cooling system to operate our high-T SQUIDs [1]. The micro-cooler system is based on a commercial desktop CryoLab unit from DEMCON kryoz [2]. It contains a two-stage MEMS micro-cooler with a base temperature of 75 K, gross cooling power of 75 mW@80 K, and temperature stability ± 50 mK.
Our high-TC dc SQUID gradiometers were fabricated from YBaCuO thin films grown by pulsed laser deposition on 10 mm × 10 mm SrTiO bicrystal substrates with 24° misorientation angle. The SQUID chip was glued onto a 0.3 mm thick silicon wafer chip carrier that was attached to the second stage of the cold head. The vacuum housing of the cold stage was made from non-magnetic material (polyethylene terephthalate, PET) and evacuated to a base pressure below 2x10 mbar. The vacuum chamber features a 0.3 mm thick sapphire window that is placed above the sensor/cold stage. We demonstrated that the equivalent magnetic flux noise of the high-T SQUID gradiometer is largely unaffected by the micro-cooler setup. The cut-off frequency of the 1/f noise in our SQUID measured on the micro-cooler was around 10 Hz. This indicates that the micro-cooler does not introduce significant magnetic fields in the vicinity of the cold stage. We thus demonstrate that such a microfluidic cooling system is a promising technology for cooling of high-T SQUIDs in practical applications.
We also used the micro-cooler system to build a prototype a magnetic ac susceptibility (ACS) system for detection of specific binding reactions between DNA target molecules and functionalized magnetic nanoparticles (fMNP) in liquid solution. The detection principle relies on changes in Brownian rotation dynamics of fMNPs. We present the results of experiments with various concentrations of magnetic nanoparticles and discuss further development of the portable magnetic bioassay system for detection of influenza virus using oligonucleotide-tagged magnetic nanoparticles with sub-picomolar sensitivity.
[1] A. Kalabukhov et al., Supercond. Sci. Technol. 29 095014 (2016).
[2] http://kryoz.nl/portfolio-item/cryolab-msg
Recommended from our members
Author Correction: Gut microbiome composition in the Hispanic Community Health Study/Study of Latinos is shaped by geographic relocation, environmental factors, and obesity.
Following publication of the original paper [1], an error was reported in the third paragraph in the section "Analysis of GMB composition and its correlates" (page 3 of the PDF). The first sentence of the text should refer to Table 2, but mistakenly refers to Table 1
Homogeneous differential magnetic assay
Assays are widely used for detection of various targets, including pathogens, drugs, and toxins. Homogeneous assays are promising for the realization of point-of-care diagnostics as they do not require separation, immobilization, or washing steps. For low concentrations of target molecules, the speed and sensitivity of homogeneous assays have hitherto been limited by slow binding kinetics, time-consuming amplification steps, and the presence of a high background signal. Here, we present a homogeneous differential magnetic assay that utilizes a differential magnetic readout that eliminates previous limitations of homogeneous assays. The assay uses a gradiometer sensor configuration combined with precise microfluidic sample handling. This enables simultaneous differential measurement of a positive test sample containing a synthesized\ua0Vibrio cholerae\ua0target and a negative control sample, which reduces the background signal and increases the readout speed. Very low concentrations of targets down to femtomolar levels are thus detectable without any additional amplification of the number of targets. Our homogeneous differential magnetic assay method opens new possibilities for rapid and highly sensitive diagnostics at the point of care
Recommended from our members
Input-dependent modulation of MEG gamma oscillations reflects gain control in the visual cortex
Gamma-band oscillations arise from the interplay between neural excitation (E) and inhibition (I) and may provide a non-invasive window into the state of cortical circuitry. A bell-shaped modulation of gamma response power by increasing the intensity of sensory input was observed in animals and is thought to reflect neural gain control. Here we sought to find a similar input-output relationship in humans with MEG via modulating the intensity of a visual stimulation by changing the velocity/temporal-frequency of visual motion. In the first experiment, adult participants observed static and moving gratings. The frequency of the MEG gamma response monotonically increased with motion velocity whereas power followed a bell-shape. In the second experiment, on a large group of children and adults, we found that despite drastic developmental changes in frequency and power of gamma oscillations, the relative suppression at high motion velocities was scaled to the same range of values across the life-span. In light of animal and modeling studies, the modulation of gamma power and frequency at high stimulation intensities characterizes the capacity of inhibitory neurons to counterbalance increasing excitation in visual networks. Gamma suppression may thus provide a non-invasive measure of inhibitory-based gain control in the healthy and diseased brain
- …